High Risk Nitrile Powder Free Glove

Heavy duty thickness and extended length offer greater barrier protection against a wide range of chemicals and dangerous substances. A dependable protection for higher risk job setting. Made of premium compounded nitrile eliminating latex allergy concern. It comes with excellent fit, comfort with greater strength and durability. Palm textured surface helps to provide secure grip. Its chlorinated powder free interior helps to promote a smooth donning and doffing experience. 

Colour

img

Product Specification

  • Material 

    Synthetic Nitrile Latex

  • Type

    Powder Free, Non-Sterile

  • Colour 

    Blue

  • Flavour (If applicable)

    N/A

  • Design & Features

    Extended Length, Palm Textured Surface, Ambidextrous, Beaded cuff, Online Single Chlorinated

  • Storage

    The gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight.

  • Shelf Life

    3 years from the date of manufacturing

  • Application

    Laboratory, Industrial, Building and Construction, Service and Repair, Emergency Aid Fields

Quality Performance

Functional Benefits

  • Heavy duty thickness and extended length for greater strength and durability
  • Provide greater barrier protection against chemicals and dangerous substances
  • An alternative solution for individuals who are allergic to Natural Rubber Latex
  • Free from latex protein, eliminating Type I Immediate Hypersensitivity reaction
  • Custom design with excellent fit and comfort
  • Palm textured provide secure grip 
  • Chlorinated powder free interior promote smooth donning & doffing experience

 

Glove Sizes

  • XS
  • S
  • M
  • L
  • XL

 

Quality Standards

  • Manufactured under QSR (GMP), ISO 9001:2015 and ISO 13485:2016 Quality Management System
  • Conforms to ASTM D6319 and EN455 Standards
  • Complies to PPE Regulation (EU) 2016/425 requirements

Physical Dimension & Physical Properties

TOP GLOVE

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • 300 ± 10
  • 76 ± 3
  • 84 ± 3
  • 94 ± 3
  • 105 ± 3
  • 113 ± 3
  • Finger : Min 0.32 ± 0.02 (12.8mil ± 0.8 mil)
  • Palm : Min 0.26 ± 0.02 (10.4mil ± 0.8 mil)
 

ASTM D6319

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • Min 220 (XS, S)
  • Min 230 (M, L, XL)
  • 70 ± 10
  • 80 ± 10
  • 95 ± 10
  • 110 ± 10
  • 120 ± 10
  • Finger: Min 0.05 (≥ 2.0 Mil)
  • Palm :  Min 0.05 (≥ 2.0 Mil)

Elongation at Break, %

  • Before Aging
     
    Min 500
  • After Aging
     
    Min 400

Tensile Strength, MPa

  • Before Aging
     
    Min 14
  • After Aging
     
    Min 14

EN 455

Size Length (mm) Palm width (mm) Thickness : Single wall (mm)
  • XS
  • S
  • M
  • L
  • XL
  • Min 240
  • ≤80
  • 80 ± 10
  • 95 ± 10
  • 110 ± 10
  • ≥110
  • N/A

Median Force at Break, N 

  • Before Aging
     
    Min 6
  • After Aging
     
    Min 6

Product Safety Conformance

CHEMICAL RESIDUE TESTED Pass

Purpose: To ensure the gloves are free from any chemical substances and safe to use.

Chemical Test (s) Test Results (μg/g)
Butylated Hydroxyanisole (BHA) Not Detected
Butylated Hydroxytoluene (BHT) Not Detected
Diphenyl Thiourea (DPT) Not Detected
Mercaptobenzothiazole (MBT) Not Detected
Tetramethylthiuram Disulphide (TMTD) Not Detected
Zinc Dibutyldithiocarbamate (ZDBC) Not Detected
Zinc Diethyldithiocarbamate (ZDEC) Not Detected
Zinc Dimethyldithiocarbamate (ZDMC) Not Detected
Zinc Mercaptobenzimidazole (ZMBI) Not Detected
Zinc Mercaptobenzothiazole (ZMBT) Not Detected
Zinc Pentamethyleneditithiocarbamate (ZPMC) Not Detected

Remark: Applicable to selected products. Please liaise with our representative for further details.

PHTHALATES TESTED Pass

Purpose: Compliance on REACH Regulation (EC) 1907/2006 Annex XVII requirements for phthalates

Chemical Test (s) Test Results (μg/g)
Dibutyl Phthalate (DBP) Not Detected
Di(2-ethylhexyl) Phthalate (DEHP) Not Detected
Di-n-octyl Phthalate (DNOP) Not Detected
Di-isononyl Phthalate (DINP) Not Detected
Di-isodecyl Phthalate (DIDP) Not Detected
Benzyl butyl Phthalate (BBP) Not Detected

 


Remark: Applicable to selected product. Please liaise with our representative for further details.

HEAVY METAL TESTED Pass

Reference: EPA Method 3052

Purpose: To ensure the gloves are free from heavy metal substances and safe to use.

Chemical Test (s) Test Results (μg/g)
Cadmium (Cd) Not Detected
Lead (Pb) Not Detected
Mercury (Hg) Not Detected
Arsenic (As) Not Detected
Antimony (Sb) Not Detected
Tin (Sm) Not Detected

Remark: Applicable to selected product. Please liaise with our representative for further details.